IXORTA AGRICULTUREManufacturer in Türkiye
Request quotation
Catalogue model · technical guide

IX-AG-MP30 Portable Water Pump Specifications, Operation & Selection Guide

A farm water-pump or irrigation unit moves water at a rated flow and head into field distribution, transfer or drip-irrigation systems.

IX-AG-MP30 Portable Water Pump machinery in a clean operating environment
IX-AG-MP30 Portable Water Pump — final configuration is defined in the signed quotation.
Model overview

What is IX-AG-MP30?

IX-AG-MP30 is an IXORTA portable water pump. A farm water-pump or irrigation unit moves water at a rated flow and head into field distribution, transfer or drip-irrigation systems. Its principal catalogue values are Rated power: 7.5 HP; Inlet / outlet: 3 in / 3 in.

Start with the IXORTA Agriculture product range, then use this model page to assess fit, operating needs and the information required for a quotation.

IX-AG-MP30 catalogue specifications

The values below come from the supplied 2026 IXORTA catalogue. Use them to build an initial shortlist, then confirm the exact configuration, options and acceptance criteria in the model-specific quotation.

IX-AG-MP30 Portable Water Pump reference data
Rated power7.5 HP
Inlet / outlet3 in / 3 in
Maximum flow1000 L/min
Maximum head30 m

Before ordering: confirm the duty, usable capacity, overall dimensions, utilities, safety package, controls, attachments and documentation for the destination market. Download the division catalogue.

Where IX-AG-MP30 sits in the range

IX-AG-MP30 is the first configuration in a 4-model range; buyers should compare it with the larger listed alternatives when production or work-envelope needs may grow.

Shortlist this model when the planned duty is close to its listed values. If the application regularly approaches a limit, compare the adjacent models below and ask IXORTA to check working margin, cycle expectations and future capacity.

Compare every water pumps and irrigation units model.

How the IX-AG-MP30 works

The operator confirms water source, suction sealing, priming, discharge route and safe engine position before starting. Flow is introduced gradually and the system is monitored for cavitation, leaks and pressure.

The safe sequence depends on the supplied guards, controls, utilities and attachments. Operators should follow the delivered manual, training and site risk assessment. For process examples and planning articles, continue to the IXORTA Agriculture industry guides.

Manufacturing and acceptance checks

Review pump casing and impeller, engine coupling, seals, frame, hose connections, guards, controls and a flow-and-head test. Irrigation assemblies also require filtration and distribution review.

A useful factory-acceptance record identifies the agreed configuration, principal components, inspection points, test material or load, observed results, open actions, documentation set, packing method and release approval. See IXORTA Agriculture project scopes for the wider delivery context.

Applications and selection questions

Typical applications

  • field irrigation
  • water transfer
  • drip-irrigation supply
  • farm reservoir service

Confirm before selection

  • required flow
  • total dynamic head
  • suction lift
  • pipe diameter
  • water quality and filtration
  • fuel and service access

A catalogue capacity alone is not enough. IXORTA should receive the normal and peak operating range, site conditions, utilities, operator experience, destination and delivery constraints before recommending a configuration. Review the division buyer FAQs before sending the enquiry.

Practical working sequence

  1. Define the job. Record material, load, output, quality and environmental requirements.
  2. Inspect before start. Check guards, fluids, fasteners, tooling or attachments, connections and the work area.
  3. Set the equipment. Apply the model manual, verified program or calibrated field setting.
  4. Prove at low risk. Run a dry cycle, first part, clean-water test or short field pass as appropriate.
  5. Monitor production. Watch load, sound, temperature, quality, flow, alignment and safety devices.
  6. Close and record. Isolate safely, clean, inspect wear and log service actions.

Use the project enquiry form to identify any required training, commissioning or operator documentation.

Maintenance priorities

  • drain and clean after dirty-water use
  • check seals, hoses and clamps
  • service engine filters and oil
  • protect from freezing and dry storage

Intervals depend on operating hours, duty, dust, heat, water quality and the surrounding environment. The delivered manual and component schedules control the final service plan. Send spare-parts and service questions through the IXORTA contact page.

Regional project planning

Field planning for the Middle East, Africa, Russia and Central Asia

Match every machine to farm size, climate, soil, crop, tractor power, hitch, PTO or hydraulic flow, seasonal work window, inland transport, operator experience and first-season spare-parts access.

For a useful export quotation, include the destination port, inland route, unloading equipment, site access, local standards, document language, commissioning responsibility and critical spare-parts expectation. Browse regional project examples.

Project enquiry

Request a IX-AG-MP30 quotation

Send the intended application, capacity, destination and site conditions. The request is routed to the IXORTA team with this division and model already identified.

Frequently asked questions about IX-AG-MP30

What is the IX-AG-MP30 Portable Water Pump used for?

A farm water-pump or irrigation unit moves water at a rated flow and head into field distribution, transfer or drip-irrigation systems. Typical applications include field irrigation, water transfer, drip-irrigation supply, farm reservoir service.

How does the IX-AG-MP30 work?

The operator confirms water source, suction sealing, priming, discharge route and safe engine position before starting. Flow is introduced gradually and the system is monitored for cavitation, leaks and pressure.

What are the catalogue specifications for IX-AG-MP30?

Rated power is 7.5 HP; Inlet / outlet is 3 in / 3 in; Maximum flow is 1000 L/min; Maximum head is 30 m. These are catalogue-listed reference values and must be confirmed in the final quotation.

What information should a buyer send for a IX-AG-MP30 quotation?

Send the application, required capacity, materials or operating conditions, utilities, destination country and port, site constraints, preferred options, project timing and installation expectations.

What should be checked before shipment?

The agreed configuration, safety equipment, dimensions, utilities, documentation, factory acceptance scope, packing, spare-parts list, installation responsibilities and destination requirements should be recorded before release.

Source and verification

This article is based on the IXORTA 2026 IXORTA Agriculture catalogue. Final technical values, options, compliance, availability and performance acceptance criteria must be confirmed in the signed quotation.

Compare IX-AG-MP30 with your project requirements

Use the enquiry form above, email the technical brief or continue by WhatsApp.